Difference between revisions of "ANSI White"

From Flashlight Wiki
Jump to navigation Jump to search
(cleanup)
Line 1: Line 1:
[[File:Ansiwhite.jpg|thumb|400px|Chromaticity chart with ANSI divisions by CCT and Cree division and subdivisions]]ANSI C78.377-2008 is a standard developed by the American National Standards Institute (ANSI) and the National Electrical Manufacturers Association (NEMA) in 2008 to standardize the description of tints in LED's and Solid State Lighting. It sets up 8 regions based on correlated color temperature (CCT), defining centers at certain coordinates and offsets from each coordinate that describe a "rectangles" on the chromaticity chart. These are shown in the graphic as red dashed rectangles (easier to see at full size).
[[File:Ansiwhite.jpg|thumb|400px|Chromaticity chart with ANSI quadrangles by CCT and Cree divisions and subdivisions]]ANSI C78.377-2008 is a standard developed by the American National Standards Institute (ANSI) and the National Electrical Manufacturers Association (NEMA) in 2008 to standardize the description of tints in LED's and Solid State Lighting. It sets up 8 points with coordinates based on correlated color temperature (CCT), and offsets from each coordinate that describe quadrangles on the chromaticity chart. These are shown in the graphic as red dashed rectangles (easier to see at full size).


# 6500K  
# 6500K  
Line 10: Line 10:
# 2700K
# 2700K


This standard was adopted by companies like [[Cree]] and [[Philips Lumileds]] to describe the tint of their LED products. They divided each ANSI rectangle into four quadrants to get bins like 1A, 1B, 1C, and 1D being divisions of rectangle 1 (6500K). Tints lying outside of the ANSI standard, above and below the rectangle, are given names like 1R, 1S, 1T, and 1U. Towards the cold end of the spectrum a non-ANSI rectangle, rectangle 0, was added. Cree subdivides regions 5, 6, 7, and 8 into even smaller subdivisions to get bins like 5A1, 5A2, 5A3, and 5A4, while Lumileds would call all of those 5A.
This standard was adopted by companies like [[Cree]] and [[Philips Lumileds]] to describe the tint of their LED products. They divided each ANSI quadrangle into four quadrants to get bins like 1A, 1B, 1C, and 1D being divisions of quadrangle 1 (6500K). Tints lying outside of the ANSI standard, above and below the quadrangle, are given names like 1R, 1S, 1T, and 1U. Towards the cold end of the spectrum a non-ANSI quadrangle, quadrangle 0, was added. Cree subdivides regions 5, 6, 7, and 8 into even smaller subdivisions to get bins like 5A1, 5A2, 5A3, and 5A4, while Lumileds would call all of those 5A.


==Further reading==
==Further reading==

Revision as of 00:03, 30 December 2010

Chromaticity chart with ANSI quadrangles by CCT and Cree divisions and subdivisions

ANSI C78.377-2008 is a standard developed by the American National Standards Institute (ANSI) and the National Electrical Manufacturers Association (NEMA) in 2008 to standardize the description of tints in LED's and Solid State Lighting. It sets up 8 points with coordinates based on correlated color temperature (CCT), and offsets from each coordinate that describe quadrangles on the chromaticity chart. These are shown in the graphic as red dashed rectangles (easier to see at full size).

  1. 6500K
  2. 5700K (cool white)
  3. 5000K
  4. 4500K
  5. 4000K (neutral white)
  6. 3500K
  7. 3000K (warm white)
  8. 2700K

This standard was adopted by companies like Cree and Philips Lumileds to describe the tint of their LED products. They divided each ANSI quadrangle into four quadrants to get bins like 1A, 1B, 1C, and 1D being divisions of quadrangle 1 (6500K). Tints lying outside of the ANSI standard, above and below the quadrangle, are given names like 1R, 1S, 1T, and 1U. Towards the cold end of the spectrum a non-ANSI quadrangle, quadrangle 0, was added. Cree subdivides regions 5, 6, 7, and 8 into even smaller subdivisions to get bins like 5A1, 5A2, 5A3, and 5A4, while Lumileds would call all of those 5A.

Further reading